gov to sftool.gov: The DS RRset for the zone included algorithm 10 (RSASHA512), but no DS RR matched a DNSKEY with algorithm 10 that signs the zone's DNSKEY RRset. See RFC 4035, Sec. 2.2, RFC 6840, Sec. 5.11. (13.248.142.184, 13.248.144.182, 13.248.149.147, 76.223.9.162, 76.223.24.135, 2600:1f14:653:bb00:b24e:739c:b87d:8fee, 2600:1f16:8f2:d500::4, UDP_-_EDNS0_4096_D_KN)
sftool.gov/A: The DS RRset for the zone included algorithm 10 (RSASHA512), but no RRSIG with algorithm 10 covering the RRset was returned in the response. See RFC 4035, Sec. 2.2, RFC 6840, Sec. 5.11. (13.248.142.184, 13.248.144.182, 13.248.149.147, 76.223.9.162, 76.223.24.135, 2600:1f14:653:bb00:b24e:739c:b87d:8fee, 2600:1f16:8f2:d500::4, UDP_-_EDNS0_4096_D_KN)
sftool.gov/AAAA: The DS RRset for the zone included algorithm 10 (RSASHA512), but no RRSIG with algorithm 10 covering the RRset was returned in the response. See RFC 4035, Sec. 2.2, RFC 6840, Sec. 5.11. (13.248.142.184, 13.248.144.182, 13.248.149.147, 76.223.9.162, 76.223.24.135, 2600:1f14:653:bb00:b24e:739c:b87d:8fee, 2600:1f16:8f2:d500::4, UDP_-_EDNS0_4096_D_KN)
sftool.gov/DNSKEY (alg 8, id 4292): The DS RRset for the zone included algorithm 10 (RSASHA512), but no RRSIG with algorithm 10 covering the RRset was returned in the response. See RFC 4035, Sec. 2.2, RFC 6840, Sec. 5.11. (13.248.142.184, 13.248.144.182, 13.248.149.147, 76.223.9.162, 76.223.24.135, 2600:1f14:653:bb00:b24e:739c:b87d:8fee, 2600:1f16:8f2:d500::4, UDP_-_EDNS0_4096_D_KN)
sftool.gov/DNSKEY (alg 8, id 7536): The DS RRset for the zone included algorithm 10 (RSASHA512), but no RRSIG with algorithm 10 covering the RRset was returned in the response. See RFC 4035, Sec. 2.2, RFC 6840, Sec. 5.11. (13.248.142.184, 13.248.144.182, 13.248.149.147, 76.223.9.162, 76.223.24.135, 2600:1f14:653:bb00:b24e:739c:b87d:8fee, 2600:1f16:8f2:d500::4, UDP_-_EDNS0_4096_D_KN)
sftool.gov/DNSKEY (alg 8, id 7732): The DS RRset for the zone included algorithm 10 (RSASHA512), but no RRSIG with algorithm 10 covering the RRset was returned in the response. See RFC 4035, Sec. 2.2, RFC 6840, Sec. 5.11. (13.248.142.184, 13.248.144.182, 13.248.149.147, 76.223.9.162, 76.223.24.135, 2600:1f14:653:bb00:b24e:739c:b87d:8fee, 2600:1f16:8f2:d500::4, UDP_-_EDNS0_4096_D_KN)
sftool.gov/NS: The DS RRset for the zone included algorithm 10 (RSASHA512), but no RRSIG with algorithm 10 covering the RRset was returned in the response. See RFC 4035, Sec. 2.2, RFC 6840, Sec. 5.11. (13.248.142.184, 13.248.144.182, 13.248.149.147, 76.223.9.162, 76.223.24.135, 2600:1f14:653:bb00:b24e:739c:b87d:8fee, 2600:1f16:8f2:d500::4, UDP_-_EDNS0_4096_D_KN)
sftool.gov/NSEC3PARAM: The DS RRset for the zone included algorithm 10 (RSASHA512), but no RRSIG with algorithm 10 covering the RRset was returned in the response. See RFC 4035, Sec. 2.2, RFC 6840, Sec. 5.11. (13.248.142.184, 13.248.144.182, 13.248.149.147, 76.223.9.162, 76.223.24.135, 2600:1f14:653:bb00:b24e:739c:b87d:8fee, 2600:1f16:8f2:d500::4, UDP_-_EDNS0_4096_D_KN)
sftool.gov/SOA: The DS RRset for the zone included algorithm 10 (RSASHA512), but no RRSIG with algorithm 10 covering the RRset was returned in the response. See RFC 4035, Sec. 2.2, RFC 6840, Sec. 5.11. (13.248.142.184, 13.248.144.182, 13.248.149.147, 76.223.9.162, 76.223.24.135, 2600:1f14:653:bb00:b24e:739c:b87d:8fee, 2600:1f16:8f2:d500::4, TCP_-_EDNS0_4096_D_N, UDP_-_EDNS0_4096_D_KN, UDP_-_EDNS0_4096_D_KN_0x20)
sftool.gov/TXT: The DS RRset for the zone included algorithm 10 (RSASHA512), but no RRSIG with algorithm 10 covering the RRset was returned in the response. See RFC 4035, Sec. 2.2, RFC 6840, Sec. 5.11. (13.248.142.184, 13.248.144.182, 13.248.149.147, 76.223.9.162, 76.223.24.135, 2600:1f14:653:bb00:b24e:739c:b87d:8fee, 2600:1f16:8f2:d500::4, UDP_-_EDNS0_4096_D_KN)
sftool.gov/DNSKEY has errors; select the "Denial of existence" DNSSEC option to see them.
sftool.gov/MX has errors; select the "Denial of existence" DNSSEC option to see them.
uzmwcpyfo3.sftool.gov/A has errors; select the "Denial of existence" DNSSEC option to see them.
sftool.gov/CNAME has errors; select the "Denial of existence" DNSSEC option to see them.